Missions

Real engineering problems on each facility, easiest first. Passing one unlocks the next.

Oil & gas production

FPSO production train

Sandbox
  • 1

    Your first shift: hand a loop back to AUTO

    The HP separator level was left in manual after maintenance and it is creeping up.

    Foundation · Control loop fundamentals · 10:00 plant time · 60 XP

  • 2

    Level into flow: restore the cascade

    FIC-100 is holding a fixed flow, so nothing is controlling the HP level — and the wells are about to change.

    Foundation · Control loop fundamentals · 12:00 plant time · 60 XP

    Locked
  • 3

    The slow swing: an over-integrated level loop

    The HP level swings every few minutes, and the whole train downstream swings with it.

    Practitioner · Controller tuning · 20:00 plant time · 100 XP

    Locked
  • 4

    Riding out a slug

    W-103's riser has started slugging, and the HP separator is running high.

    Practitioner · Abnormal situations · 20:00 plant time · 100 XP

    Locked
  • 5

    The loop that wouldn't settle

    The interface level has been cycling for days. Retuning hasn't helped. Find out why.

    Advanced · Instruments & valves · 15:00 plant time · 150 XP

    Locked
  • 6

    Trust, but verify: a drifting transmitter

    LIC-100 is holding 50 % perfectly. The HP separator may not be at 50 %.

    Advanced · Instruments & valves · 15:00 plant time · 150 XP

    Locked
  • 7

    Compressor trip!

    The gas compressor is about to trip. Keep the plant up and the flare small.

    Advanced · Abnormal situations · 12:00 plant time · 150 XP

    Locked
  • 8

    Water breakthrough

    Two wells are watering out. Keep the crude dry and the sea clean.

    Advanced · Operations & optimisation · 20:00 plant time · 150 XP

    Locked
  • 9

    Back from a shutdown

    The plant tripped overnight. Find out why, and bring it back safely.

    Expert · Safety systems · 25:00 plant time · 220 XP

    Locked
  • 10

    Push for production

    The chokes are conservative. Produce as much oil as the plant will safely take.

    Expert · Operations & optimisation · 20:00 plant time · 220 XP

    Locked

Refining & petrochemicals

Crude charge heater

Sandbox
  • 1

    Bring the coil outlet to temperature

    The heater is running cold on manual. Get the crude to 360 °C and hand it to the controller.

    Foundation · Control loop fundamentals · 10:00 plant time · 60 XP

  • 2

    Fuel gas swings: close the cascade

    The fuel gas header is swinging and the COT swings with it. The fix is already installed.

    Practitioner · Controller tuning · 15:00 plant time · 100 XP

    Locked
  • 3

    Hot tubes: balance the passes

    One pass is running hot. Protect the tubes without losing throughput.

    Advanced · Abnormal situations · 15:00 plant time · 150 XP

    Locked
  • 4

    Burn less fuel: trim the excess air

    The heater is running with far too much air. Save fuel — and stay safe when the afternoon heats up.

    Advanced · Operations & optimisation · 20:00 plant time · 150 XP

    Locked
  • 5

    Heater trip and relight

    The heater is about to trip. Bring it back the way the burner management procedure says.

    Expert · Safety systems · 20:00 plant time · 220 XP

    Locked

Gas processing & LNG

Gas compression & dehydration

Sandbox
  • 1

    Gas to flare: close the speed cascade

    The compressor is running slow on manual and the plant is flaring gas it should be exporting.

    Foundation · Control loop fundamentals · 10:00 plant time · 60 XP

  • 2

    Export shut-in: keep the compressor out of surge

    The pipeline is about to shut in your export. The anti-surge controller is in manual.

    Practitioner · Abnormal situations · 10:00 plant time · 100 XP

    Locked
  • 3

    A hot afternoon: keep the gas dry

    The afternoon heat will push wet gas into the pipeline. Keep it on specification without cooking the glycol.

    Advanced · Operations & optimisation · 20:00 plant time · 150 XP

    Locked
  • 4

    Contactor upset: find what is wrong

    Water in the export gas is climbing and the contactor is losing glycol. Work out why, then fix it.

    Advanced · Instruments & valves · 15:00 plant time · 150 XP

    Locked
  • 5

    Compressor trip: restart on recycle

    K-300 has tripped and the plant is flaring everything. Find why, and bring it back safely.

    Expert · Safety systems · 15:00 plant time · 220 XP

    Locked
Missions · LensaSim Plant